DFI 250 DIGITAL INDICATOR QUICK START MANUAL www.cooperinstruments.com PH: (540) 349-4746 • FAX: (540) 347

Pagina 2 - CONTENTS

CF 146 8 V- Rev. 1.0 - 003R-620-100 7.1.1 Trade Critical Settings Trade critical settings can affect calibration and/or legal for trade performance

Pagina 3 - 1.0 INTRODUCTION

CF 146 9 V- Rev. 1.0 - 003R-620-100 GROUP (GRP) ITEM (ITM) SELECT (SEL) EDIT (EDT) Underline = Defaults OK DP Decimal Point Posi

Pagina 4

CF 146 10 V- Rev. 1.0 - 003R-620-100 (L1, L2, L3, L4, L5) <ITM> to return to CLR.LIN. DIR.ZER Direct Zero Calibration (Current weight displ

Pagina 5 - 6.1 Cable Connections

CF 146 11 V- Rev. 1.0 - 003R-620-100 TARG.HI Target for Overweight Setpoint 1 (Output 1) -99999 to 999999 Default = 000000 Accept TARG.LO Target

Pagina 6 - 6.4 Auxiliary Connections

CF 146 12 V- Rev. 1.0 - 003R-620-100 8.0 ERROR MESSAGES 8.1 Weighing Errors • Check Setup = This item can be checked on site by service personnel.

Pagina 7 - 6.4.5 Outputs

CF 146 13 V- Rev. 1.0 - 003R-620-100 too low or too high. (E0100) The digital setup information has been lost. Re-enter setup (E0200) The calibr

Pagina 8 - 6.5 Connecting Shields

CF 146 ii V- Rev. 1.0 - 003R-620-100 CONTENTS 1.0 INTRODUCTION...

Pagina 9 - 7.1 Calibration Counter

CF 146 1 V- Rev. 1.0 - 003R-620-100 1.0 INTRODUCTION This manual contains information on the installation, calibration and setup of the instrument.

Pagina 10

CF 146 2 V- Rev. 1.0 - 003R-620-100 Drive Outputs 2 isolated transistor drive outputs (300mA total at 50VDC) Battery Backed Clock Calendar Batter

Pagina 11

CF 146 3 V- Rev. 1.0 - 003R-620-100 5.4 GSE-LINK The optional GSE-LINK cable can be used to transfer setup and calibration information from a PC (

Pagina 12

CF 146 4 V- Rev. 1.0 - 003R-620-100 6.3 Load Cell Connection The instrument may be connected for either 4-wire or 6-wire operation. For more inform

Pagina 13

CF 146 5 V- Rev. 1.0 - 003R-620-100 RS-232 - Instrument to PC using COM Port (DB25) 6.4.2 Printer Connections (RXD/TXD, GND and DTR) RS-232 – In

Pagina 14 - 8.3 Diagnostic Errors

CF 146 6 V- Rev. 1.0 - 003R-620-100 • This configuration allows for the direct connection of the instrument outputs to most types of PLC. • The vol

Pagina 15 - 9.0 WARRANTY REPAIR POLICY

CF 146 7 V- Rev. 1.0 - 003R-620-100 6.5.1 Cable Shield Connection and Earthing • Care should be taken when connecting shields to maximize EMC or RF