Pagina 1 - USER’S GUIDE

DFI INFINITY CS STRAIN METER/CONTROLLER USER’S GUIDE www.cooperinstruments.com PH: 540-349-4746 • FAX:

Pagina 2 - CONTENTS

DFI INFINITY CS (V- M3598/N/0906) 7 CF 70 • To check or change the 115 or 230 Vac power jumpers. • To install or remove jumpers on the main board.

Pagina 3

DFI INFINITY CS (V- M3598/N/0906) 8 CF 70 Figure 3-2 Main Board Jumper Positions Figure 3-3 Upper Isolated Analog Output Option Board Installatio

Pagina 4 - PREFACE

DFI INFINITY CS (V- M3598/N/0906) 9 CF 70 Table 3-1 S3 Jumper Functions 3.3 Panel Mounting Figure 3-4 Meter – Exploded View 1. Cut a ho

Pagina 5 - 1.0 INTRODUCTION

DFI INFINITY CS (V- M3598/N/0906) 10 CF 70 Connections with ”typical wire colors” +E = Positive Excitation (red) -E = Negative Excitation (black)

Pagina 6 - 2.0 ABOUT THE METER

DFI INFINITY CS (V- M3598/N/0906) 11 CF 70 Figure 3-9 Current Input Connections with Internal Excitation Figure 3-10 Current Input Connections wi

Pagina 7 - 2.4 Front of the Meter

DFI INFINITY CS (V- M3598/N/0906) 12 CF 70 Table 3-2 AC-Power Connections

Pagina 8 - 2.5 Back of the Meter

DFI INFINITY CS (V- M3598/N/0906) 13 CF 70 Figure 3-14 Analog Output Connections Figure 3-15 Relay Output Connections Figure 3-16 Isolated Anal

Pagina 9 - 2.6 Disassembly

DFI INFINITY CS (V- M3598/N/0906) 14 CF 70 4.0 CONFIGURING THE METER Refer to Table 6-1 for a summary list of menu configuration. For first-time u

Pagina 10 - 3.0 GETTING STARTED

DFI INFINITY CS (V- M3598/N/0906) 15 CF 70 • ‘C’ switch should be closed or down. • ‘X’ switch is used to control excitation (refer to Table 2-3 t

Pagina 11

DFI INFINITY CS (V- M3598/N/0906) 16 CF 70 4.3.2 Scaling without Known Loads To scale without known inputs, calculate input values based on transduc

Pagina 12 - 3.4 Connecting Sensor Inputs

DFI INFINITY CS (V- M3598/N/0906) ii CF 70 CONTENTS PREFACE ...

Pagina 13

DFI INFINITY CS (V- M3598/N/0906) 17 CF 70 You may use Reading Configuration to configure your meter for the following: • To select ratiometric o

Pagina 14 - 3.5 Connecting Main Power

DFI INFINITY CS (V- M3598/N/0906) 18 CF 70 4.5 Selecting a Display Color Refer to Table 6-1 for a summary list of menu configuration.Selectin

Pagina 15

DFI INFINITY CS (V- M3598/N/0906) 19 CF 70 • = Setpoint 1 assigned to net reading (Default) • = Setpoint 1 assigned to gross reading 2. Press the

Pagina 16

DFI INFINITY CS (V- M3598/N/0906) 20 CF 70 1. Press the MENU button until the meter shows . 2. Press the X/TARE button. The meter shows the last p

Pagina 17 - 4.0 CONFIGURING THE METER

DFI INFINITY CS (V- M3598/N/0906) 21 CF 70 To reset latched alarms you must: 1. Input a signal OUT of the alarm zone 2. Then press SETPTS and then

Pagina 18

DFI INFINITY CS (V- M3598/N/0906) 22 CF 70 equal to the meter’s display and/or any engineering units you require. You may scale the output for dire

Pagina 19

DFI INFINITY CS (V- M3598/N/0906) 23 CF 70 9. Press the X/TARE button to show the existing value. 10. Change the value of Read 2 to 100.0 by pressin

Pagina 20

DFI INFINITY CS (V- M3598/N/0906) 24 CF 70 • = Medium Brightness • = Low Brightness • = High Brightness(Default) 3. Press the S/NT/GRS button t

Pagina 21

DFI INFINITY CS (V- M3598/N/0906) 25 CF 70 6.0 MENU CONFIGURATION DISPLAYS Not all items display on standard meters. Table 6-1 Menu Configuration Di

Pagina 22

DFI INFINITY CS (V- M3598/N/0906) 26 CF 70 MENU X/TARE S/NT/GRS R.1= (Ratiometric Reading) (Non-ratiometric reading) R.2= (1µV resolution for

Pagina 23

DFI INFINITY CS (V- M3598/N/0906) iii CF 70 4.12 Using Lock Out Configuration ...

Pagina 24

DFI INFINITY CS (V- M3598/N/0906) 27 CF 70 MENU X/TARE S/NT/GRS 0.1 = (Analog output is enabled) (Analog output is disabled) 0.2 = (Analog ou

Pagina 25

DFI INFINITY CS (V- M3598/N/0906) 28 CF 70 Table 6-2 Run Mode Displays Display X/TARE S/NT/GRS RESET Description / Displays NET or GROSS readi

Pagina 26

DFI INFINITY CS (V- M3598/N/0906) 29 CF 70 ACCURACY AT 25oC Max Error Strain: ±0.03% of reading, ± 1 count Span Tempco: 50 ppm/°C Step Respons

Pagina 27 - 5.0 DISPLAY MESSAGES

DFI INFINITY CS (V- M3598/N/0906) 30 CF 70 ENVIRONMENT Operating Temperature: 0° to 50°C (32° to 122°F) Storage Temperature: -40° to 85°C (-4

Pagina 28 - MENU X/TARE S/NT/GRS

DFI INFINITY CS (V- M3598/N/0906) 31 CF 70 9.0 FACTORY PRESET VALUES Table 9-1 Factory Preset Values MENU ITEM FACTORY PRESET VALUES Input Type:

Pagina 29

DFI INFINITY CS (V- M3598/N/0906) 32 CF 70 • Power to Input/Output: 2300 Vac (3250 Vdc) • Power to Input/Output: 500 Vac (720 Vdc) (Low Vo

Pagina 30

DFI INFINITY CS (V- M3598/N/0906) 33 CF 70 * Technical description of the defect: In order to properly repair a product, it is absolutely necessary

Pagina 31 - 8.0 SPECIFICATIONS

DFI INFINITY CS (V- M3598/N/0906) 1 CF 70 PREFACE Manual Objectives This manual shows you how to set up and use the Programmable Digital Meter. Sta

Pagina 32

DFI INFINITY CS (V- M3598/N/0906) 2 CF 70 NOTE: provides you with information that is important to successfully setup and use the Programmable Dig

Pagina 33 - MECHANICAL

DFI INFINITY CS (V- M3598/N/0906) 3 CF 70 • Use electrical wires with adequate size to handle mechanical strain and power requirements. Install wi

Pagina 34 - 9.0 FACTORY PRESET VALUES

DFI INFINITY CS (V- M3598/N/0906) 4 CF 70 RP38 19-in. Rack Panel for three (3) 1/8 DIN instruments 2.4 Front of the Meter Figure 2-1 shows each p

Pagina 35 - WARRANTY REPAIR POLICY

DFI INFINITY CS (V- M3598/N/0906) 5 CF 70 MENU Button In the Run Mode, press the MENU button to terminate the current measuring strain and enter y

Pagina 36

DFI INFINITY CS (V- M3598/N/0906) 6 CF 70 Table 2-2 Connector Description Connector Description TB1-1 TB1-2 TB1-3 TB1-4 TB1-5 TB1-6 TB1-7 TB1-8 TB1-